There are several versions of interface to EC motor available:
EC with Hall sensors 8 Wires connection 3 Phases for power |
|
EC sensorless 3 Wires connection 3 Phases for power Typically used for Fans/Blowers |
|
EC with Hall or sensorless 3 Wires connection Signal for speed and direction |
For applications with fixed speed and direction, 2 wire connection only possible (VCC and GND).